Validation and benchmarks

How the Atuund simulation compares with measurements taken in real rooms.

Public benchmark

A seminar room

BRAS is a public benchmark from RWTH Aachen University and TU Berlin: real rooms, measured and published as a reference for room simulation. In its seminar room, the Atuund simulation of how sound dies away is within about 10 % of the measurement.

Decay time
Reverberation time
Clarity

MeasuredAtuund simulation

10 %
Between the simulated and the measured time for sound to die away
10 positions
Pairs of loudspeaker and microphone across the room
100 Hz to 4 kHz
From the bass through the range of speech

Measured by Atuund

A small office

Bass changes from one spot to the next in any room. In this small office the simulation called those changes at four positions ahead of the measurement, to within about 3 dB.

MeasuredPredictedLevel in dB, relative to the average of the four positions.
3 dB
Between the prediction and the measurement
4 positions
Across the room, from 60 to 220 Hz
17 dB
A dead spot in the bass, right where the simulation said it would be

Tell us about your room

Write to projects@atuund.com, or send us a note.